Electrical Infrastructure Engineering

SCADA DESIGN — IEC 61850 COMPLIANT

End-to-end SCADA and substation automation design for utilities, renewable energy and industrial plants, from architecture through to FAT and commissioning support.

SCADA Systems Delivered

80+

Max Voltage

765kV

Countries Active

10+

Get Expert Consultation

Our specialists respond within 24 hours with a detailed technical assessment.

Services Required

Full Scope

WHAT'S INCLUDED IN OUR SCADA SCOPE

SCADA Architecture Design

Master station, RTU/gateway architecture, communication topology and redundancy design for control centre integration.

RTU & Gateway Programming

Configuration of RTUs, protocol gateways (DNP3, IEC 104, Modbus) and data point mapping to control centre SCADA.

Cybersecurity Design

IEC 62351 compliant security architecture, RBAC implementation, network segmentation, VPN and audit logging design.

IEC 61850 Engineering

SCD file development, logical node mapping, GOOSE messaging, MMS configuration and IED interoperability testing.

HMI & Mimic Development

Operator HMI screen design, single-line mimic diagrams, alarm management and trending configuration for control rooms.

FAT & Commissioning Support

Factory acceptance test procedures, site acceptance test plans and commissioning support for SCADA integration.

NOT SURE WHICH SCADA PROTOCOL FITS YOUR NETWORK?

Our automation engineers will assess your existing infrastructure and recommend the optimal solution within 48 hours.

Our Process

FROM ARCHITECTURE TO LIVE OPERATIONS

01

SYSTEM ARCHITECTURE

Define SCADA architecture, redundancy and failover strategy based on control centre requirements, security standards and communication infrastructure review.

02

IED & RTU CONFIGURATION

Configure IEDs, RTUs and protocol gateways. Develop IEC 61850 SCD files, data point lists and communication schedules. Long-lead hardware ordered within 2 weeks.

03

HMI & DATABASE BUILD

Build master station database, operator HMI displays and alarm management system. Configure historian, trending and reporting functions parallel with hardware build.

04

FACTORY ACCEPTANCE TEST

Conduct end-to-end FAT with simulated field inputs. Verify all data points, controls, alarms, interlock logic and SCADA communications before site mobilisation.

05

SITE COMMISSIONING

Carry out SAT on site including loop checks, signal verification, telecontrol testing with control centre and 72-hour operational trial run before handover.

Capabilities

Technical Specifications

Protocols Supported
IEC 61850, IEC 60870-5-104, DNP3, Modbus TCP/RTU, OPC-UA
Communication Media
Fibre optic, Ethernet, MPLS, 4G/LTE, satellite backup
Cybersecurity
IEC 62351, NERC CIP aligned, network segmentation, RBAC
SCADA Platforms
GE Cimplicity, ABB MicroSCADA, Siemens SICAM, OSIsoft PI
IED Compatibility
ABB, Siemens, GE, Schneider, SEL, Alstom relays
Standards Followed
IEC 61850, IEC 60870, IEEE C37.1, NIST 800-82
Deliverables
SCD files, HMI screens, data point lists, FAT/SAT reports