Full Scope
WHAT'S INCLUDED IN OUR M&E design SCOPE
LV Auxiliary Power Systems
AC and DC auxiliary supply design, UPS sizing, LV switchboard layouts, distribution boards and cable schedules.
HVAC & Ventilation Design
Thermal load calculations, HVAC system design for control rooms, relay rooms, battery rooms and transformer bays.
Fire Detection & Suppression
Addressable fire detection system design, transformer deluge system, clean agent suppression and alarm panel layout.
Battery & Charger Systems
110V and 48V DC battery system design, charger sizing, battery room ventilation and DC distribution schematics.
Lighting & Small Power
Normal and emergency lighting design, small power layouts, external compound lighting and lux level calculations.
Building Management Systems
BMS design for HVAC control, energy monitoring, access control integration and remote alarm reporting via SCADA.
Our Process
FROM LOAD SCHEDULE TO IFC DRAWINGS
01
LOAD SCHEDULE DEVELOPMENT
Collate all auxiliary loads from primary plant, protection, SCADA and building services. Develop LV auxiliary load schedule, UPS sizing and DC system requirements.
02
CONCEPT M&E DESIGN
Prepare concept LV single-line diagrams, HVAC schematics, fire system layout and lighting scheme for client review and coordination with civil and primary plant.
03
DETAILED ELECTRICAL DESIGN
Produce LV distribution schematics, panel GA drawings, cable schedules, containment layouts and equipment specifications ready for procurement.
04
MECHANICAL SERVICES DESIGN
Complete HVAC duct layout, equipment schedules, fire detection layouts, BMS schematics and building services drawings to IFC standard.
05
SITE SUPPORT & AS-BUILT
Provide RFI responses and site inspection support during M&E installation. Compile as-built drawings and O&M manuals for client handover.
Capabilities
Technical Specifications
DC Systems | 110V, 48V, 24V DC; VRLA and lithium-ion battery options |
UPS Ratings | 1 kVA to 200 kVA, online double conversion topology |
HVAC Standards | ASHRAE 90.1, IS 1391, BS EN 15232, CIBSE Guides |
Fire Standards | BS 5839, NFPA 72, IS 2189, FM Global for transformer areas |
Lighting Standards | CIBSE LG7, IS 1944, EN 12464-1 lux level compliance |
Software Used | AutoCAD MEP, Revit MEP, Dialux, Amtech ProDesign |
Deliverables | LV SLDs, HVAC layouts, fire drawings, cable schedules, O&M |